For the associated box gutter outlet.
Box gutter sump guards.
Overflow devices need to discharge to the atmosphere in such a way as to prevent damage to buildings and property.
The total flow is used to size the sump and overflow.
Sump with a side overflow device sumps do require an increase in the depth of flow in the box gutter and gutters are to be fitted with either.
At this stage plan the connection to the downpipe.
However by definition to have a sump somewhere along the gutter implies that there will be flow approaching the sump from two sides.
Establish the sump location this should be the lowest point in the box gutter.
Box gutter slope slope should be within the range of 1 40 to 1 200.
The total flow is used to size the sump and overflow.
Refer to hints for box gutter design marking and cutting the sump spigot mark cut sump hole dress the cut out to neatly fit to the sump decide on the position of the spigot mark and cut the hole.
It is usually advisable to install a sump guard protector with an overflow fitted to it so as you can also insure against foreign material flowing down the downpipes and minimizing a blockage in the downpipe or the storm water thus elevating the chances of a flow into the building of water egress.
The side with the maximum flow is used to size the box gutter.
Rainheads are an essential design element for buildings where internal box or trough gutters are used.
Dirt tends to accumulate in the box gutter.
A rainhead or sump is a container located between the gutter and downpipe that aids the flow of water away from the roof.